Daily Post-Shift Maintenance (Performed every shift)
Machine Cleaning: Use dry compressed air to remove copper-aluminum spatter and metal debris from the equipment surface and welding torch nozzle; direct washing of electrical components with water is strictly prohibited.
Basic Checks: Verify there are no leaks in the gas lines and that the cooling system water level is normal; inspect cable insulation for damage and ensure the grounding wire is securely connected.
Workstation Wrap-up: Clear welding slag and waste from the work surface; shut off gas, water, and main power supplies; and log any equipment operational anomalies observed during the day.
Weekly In-Depth Maintenance
Cooling System Cleaning: Remove heat dissipation filters from the welding power source and electrical control cabinet; clean off accumulated dust to ensure smooth airflow and prevent core components from overheating.
Wire Feed Mechanism Calibration: Inspect wire feed wheel grooves for wear; clean copper-aluminum metal powder from the wire feed conduit and use compressed air to back-purge and clear any blockages.
Motion Accuracy Verification: Run production line stations under no-load conditions; confirm smooth operation (without sticking) of transmission rails and conveyor rollers; and test the safety interlock function of the emergency stop button.